394 Battery Powered Vacuum Pump Pick Up Tool

SKU: H394-01

Hakko
Availability:

In stock


  • Battery-powered suction pick-up tool with built-in vacuum pump
  • Max. pick-up suction capacity is 120gf
  • Antistatic material is used for safe use in electronics

£178.18 Excl. VAT

In stock

A minimum sub total of £250.00 is required, You need an additional £250.00 to proceed through to the checkout.

For customers in the Republic of Ireland, please contact us for a quote including shipping and customs charges.

Request quote

Cordless suction pick-up tool

  • Ultra-compact high powered pump eliminates need for a power cord and an air tube.
  • Continuous suction allows easy handling of objects.
  • Soft touch switch
  • Pen-type body is easy to fit into your hand.
  • Utilizes antistatic material
  • Nozzle with a stopper
    The stopper prevents the nozzle nib from shooting through the pad, damaging components, and causing suction failures.
  • Intended Works
    Semiconductor-related works
    Pick-up of SMDs
    Surface mount PCB assembly
    Conveyance of ICs

H K Wentworth - HAKKO UK and Ireland distributor

The pick-up tool is designed to suck up micro components used for PCBs, etc. and not to absorb dust. If used to absorb dust, it may become inoperable due to the clogging of filters mounted inside.

Specifications of pad
MaterialElectrically conductive silicone rubber
Heatproof temperatureApproximately 150°C
Resistance value104Ω to 106Ω
Indication of pad replacementWhen any crack or tear is found during a visual check, or objects cannot be sucked up efficiently

Nozzle single use

NozzleApplications
Part No.Name/DescripationShapeStamped*
A1164Bent nozzle /0.4mm
(OD 0.7mm)
H K Wentworth - HAKKO UK and Ireland distributor22Chip resistors, other tiny components
A1198Bent nozzle
/0.26mm
(OD 0.5mm)
H K Wentworth - HAKKO UK and Ireland distributor25Usable for 0603 chip

*Only these 2 shapes are available for single use.
How to distinguish each nozzle.

Use Nozzle with pad
Nozzle

Part No.A1165A1486
Name/ DescriptionBent nozzle /1.1mmStraight nozzle /1.1mm
Outside
Diameter
1.65mm1.65mm
FigureH K Wentworth - HAKKO UK and Ireland distributorH K Wentworth - HAKKO UK and Ireland distributor

Pad

Part No.A1166A1312A1167A1311A1166A1312A1167A1311
Name/
Description
Pad
/o3
Pad
/o5
Pad
/o7
Pad
/o10
Pad
/o3
Pad
/o5
Pad
/o7
Pad
/o10
FigureH K Wentworth - HAKKO UK and Ireland distributorH K Wentworth - HAKKO UK and Ireland distributorH K Wentworth - HAKKO UK and Ireland distributorH K Wentworth - HAKKO UK and Ireland distributor
Pick-up Performance6gf40gf80gf120gf6gf40gf80gf120gf
Set Examples
(using 392 as an example)
H K Wentworth - HAKKO UK and Ireland distributorH K Wentworth - HAKKO UK and Ireland distributorH K Wentworth - HAKKO UK and Ireland distributorH K Wentworth - HAKKO UK and Ireland distributor

*The pick-up performance shown above slightly differs depending on the surface of the object.

Usage/Applications

With the bent nozzle accessory, 0603-size components can be suctioned.
H K Wentworth - HAKKO UK and Ireland distributor0603-sized chip resistors are extreme micro-components that are often incorporated into devices such as mobile phones.
If they are manually picked up with tweezers, it requires high-precision manual dexterity so that they will not be flicked and lost.
For the HAKKO 394, a very fine bent nozzle with 0.26mm hole diameter (A1198) which can be used for 0603-sized components is available. The nozzle ensures safe pick-up operation in continuous suction mode.
With the best suited pad selectable from a wide variety of pads, delicate bulb-shaped components can be safely picked up
Four types of pads in sizes of φ3, φ5, φ7 and φ10 respectively are available for HAKKO 394.
Suction pick up can be continuously and easily performed only by matching the pad to the size of the suction object.
Also, the stopper function of the HAKKO 394, which is enabled when a pad is used, prevents the suction object from being damaged.
H K Wentworth - HAKKO UK and Ireland distributor

Packing List

NameContentsAccessories
HAKKO 394UnitBent Nozzle/1.1mm(with stopper) Pad/5 mm Pad/10 mm AAA alkaline battery

Specifications

Model No.394
Power supplyTwo size AAA batteries
PadConductive silicone rubber
Battery lifeApprox. 30,000 suction cycles (with alkaline batteries)
Suction capacity120gf (with padΦ10mm)
Dimensions130(W)×29(H)×22(D)mm
Weight43g
* Weight (w/o batteries, nozzle, pad)

Service life of battery

Pickup repetition limit *1Continuous pickup time *2
Approx, 30,000 pickup times ( With alkaline batteries )Approx, 15 hours
*1. 26 mm x 26 mm QFP is pickup for 2 seconds using a 10 mm dia pad and then released for 1 second. This cycle is repeated cominuously unit the QFP is no longer picked up. *2. This is the time period from the moment 26 mm x 26 mm QFP starts being pickup using a 10 mm dia pad to the moment the QFP drops.

Replacement Parts

 Part No.NameSpecifications 
A1165Bent nozzlewith stopper, Φ1.1mmBuy
A1312PadΦ5mmBuy
A1311PadΦ10mmBuy
A1164Bent nozzleΦ0.4mmBuy
A1198Bent nozzleΦ0.26mmBuy
A1486Straight nozzlewith stopper, Φ1.1mmBuy
A1166PadΦ3mmBuy
A1167PadΦ7mmBuy
B2690Jointwith filterBuy
B2692Silicone tubewith filterBuy
Weight0.112 kg