FA-430 HEPA Compact Fume Extraction Unit

SKU: HFA430-13

Hakko
Availability:

Low stock – Order soon


  • Compact and Quiet Fume Extraction Unit.
  • HEPA filter (High Efficiency Particulate Air Filter)
  • Filters out 99.97% of particles greater than 0.3m
  • Recommended for quiet laboratory and office
  • Duct Set NOT included, please purchase separatel

£861.64 Excl. VAT

Low stock – Order soon

A minimum sub total of £250.00 is required, You need an additional £250.00 to proceed through to the checkout.

For customers in the Republic of Ireland, please contact us for a quote including shipping and customs charges.

Request quote

Duct set (HAKKO C1571 Duct Set Rectangular Nozzle/HAKKO C1572 Duct Set Round Nozzle) is not included in FA-430 unit. Please purchase Duct set(s) when you order FA-430 unit.

FA-430 Compact Fume Extraction Unit

The Hakko FA430-13 Smoke and Fume Extractor is specially designed for use in the electronics soldering process by extracting the contaminated air directly at the source. The three stage filtering system returns purified air to the area using a HEPA (High Efficiency Particulate Air filter).

Its light, compact design and quiet operation make it ideal for laboratories or office spaces providing powerful fume extraction where full scale extraction is not an option.

Optional parts are available to negate the effect of air conditioning on the extraction airflow to further improve efficiency.

HEPA filter captures 99.97% of particles greater than 0.3m

FA430 Compact Fume Extraction Unit provides excellent filtering efficiency, 99.97% of particles greater than 0.3m, by HEPA filter.

FA430-13 HEPA Compact Fume Extraction Unit

FA430-13 HEPA Compact Fume Extraction UnitFA430-13 HEPA Compact Fume Extraction Unit

Quiet operation and powerful suction.

Exhaust noise has been reduced without sacrificing suction performance by the addition of a silencer unit to the exhaust outlet to ensure smooth air outflow. A high-performance motor with 1,500 Pa of static pressure provides powerful suction and quiet operation.

Noise level dB (A)Air volume m3/min
HIGH534.7
MEDIUM503.7
LOW442.8
FA430-13 HEPA Compact Fume Extraction Unit

*Values measured when the unit was used with a 60 Hz power supply.

Catch harmful smoke with freestanding ducts and adjustable air volume to suit your working environment

Is your smoke absorber affected by air conditioning Are you fed up with having to re-adjust ducts after every line change The HAKKO FA-430 fume extractor is the answer to your problems.

Airflow adjustment

Three airflow modes are available: High, Medium, and Low. Significantly improve your working environment by using an airflow volume that suits the worksite and the job.

  • Low mode: Not easily affected by the surrounding environment. For use in small, quiet locations. (For when low-noise operation is a priority.)
  • Medium mode: For normal use.
  • High mode: For use in locations that are significantly affected by the surrounding environment. (For when suction performance is a priority.)

What do you mean by “surrounding environment”

Smoke flows in unexpected directions due to a variety of factors; not just because of the influence of air conditioning. High mode is recommended if your worksite is situated near a doorway, in a spot where people continuously pass by, near the exhaust outlet of a large machine, or in a similar location. It is possible to use low mode in laboratories and other places where these kinds of influences are limited.

Freestanding ducts

Ducts can be bent or lengthened as desired and maintain their shape after adjustment, letting you place them exactly where suction is needed. Say goodbye forever to ducts that are long, heavy, and hard-to-handle.

LengthWeight
Duct for HAKKO FA-4301.2m0.6kg
FA430-13 HEPA Compact Fume Extraction UnitH K Wentworth - HAKKO UK and Ireland distributor
Photo above:
Bends and stretches freely for perfect placement!
Lightweight and compact, the HAKKO FA430 Compact Fume Extraction Unit weighs only 7.5 kg. Built-in handles allow the fume extractor to be moved easily, facilitating line changeovers.*HAKKO FA430 Compact Fume Extraction Unit weighs 35% less than previous models
H K Wentworth - HAKKO UK and Ireland distributorH K Wentworth - HAKKO UK and Ireland distributorH K Wentworth - HAKKO UK and Ireland distributorH K Wentworth - HAKKO UK and Ireland distributor
If the duct is mounted directly above, it can be difficult to see the workpieceDuct is mounted on the worktable to provide excellent suction performance

H K Wentworth - HAKKO UK and Ireland distributor

Usage/Application

Proper installation of the pre-filter

  • Proper installation
    Install the pre-filter inside the frame of the main filter as shown in image 1.
    Be sure to check that there are no gaps at the corners as shown in image 2.
    H K Wentworth - HAKKO UK and Ireland distributor
  • Improper installation
    If the pre-filter is not installed properly as shown in images 3 and 4, the main filter will degrade its original performance quickly.H K Wentworth - HAKKO UK and Ireland distributor

Note: Some processes may involve the use of highly corrosive substances and are not recommended for use with the FA430.

Packing List

Model No.Packing List
FA-430
  • Main unit,
  • Power cord (B2425)
  • Cap (B3619)
  • Main filter (A1573)
  • Pre-filters (x10) (A1572)
  • Instruction manual
Duct set (C1571/C1572) is NOT included in FA-430 unit. Please purchase Duct set(s) when you order FA-430 unit.
Model No.Packing List
Duct Set C1571 (With rectangular nozzle)
  • Duct (Φ 55mm x 1.2m)
  • Adapter (B3620)
  • Rectangular nozzle (B3622)
  • Net (B3625)
  • Instruction manual
Buy Now
Duct Set C1572 (With round nozzle)
  • Duct (Φ 55mm x 1.2m)
  • Adapter, (B3620)
  • Round nozzle (B3623)
  • Net, (B3625)
  • Instruction manual
Buy Now

Specifications

Model No.FA-430
Power consumption110W
Noise level50dB (MEDIUM mode)
Maximum suction capacitywith single duct : MAX. 4.1m3/min. (145cfm) with two ducts : MAX. 4.7m3/min. (167cfm)
Filtering efficiency99.97% 0.3µm (LOW, MEDIUM mode) 99.96% 0.3µm (HIGH mode)
Static pressure1,500Pa
Duct set (sold separately)Length of duct : Φ55mm×1.2m (ESD SAFE)
Dimensions330(W)×366(H)×343(D)mm
Weight7.5kg
* Filtering efficiency is an initial value of collection efficiency based on counting method for airborne dust collected by a single plate of filter (unfolded). * Noise level is measured at a distance of 1 m from the face of unit in an anechoic room. * Net in duct sets are not protected against electrostatic discharge.

Optional / Recommended Extras

ImagesPart NumberDescriptionAvailability
C1571 Duct Set Rectangular NozzleC1571Duct set with rectangular type nozzleBuy Now
C1572 Duct Set Round NozzleC1572Duct set with round type nozzleBuy Now
B3642 Duct φ55mmx1.2mB3642Duct Φ55mm×1.2mBuy Now
B3620 AdapterB3620AdapterBuy Now
B3621 Adapter 3 inchB3621Adapter 3 inchBuy Now
B3622 Nozzle/rectangular typeB3622Nozzle/rectangular typeBuy Now
B3623 Round Type Nozzle For the FA-430B3623Nozzle/round typeBuy Now
B3625 Net (qty 5)B3625Net (qty 5)Buy Now
B2410 Duct φ75mm x 2mB2410Duct/2m Φ75mm×2mBuy Now
B2416 Duct band (qty 2)B2416Duct band (qty 2)Buy Now
B2418 Bench Top Hood / Plenum ClearB2418Bench top plenum/clearBuy Now
-When using an independent duct
Part No.Part NameNotes
B3642Ductø55 x 1.2 m photo:FH800-03SVBuy Now
B3620AdapterFor attaching duct to main unit. photo:FH800-03SVBuy Now
-Choose from one of 2 types of nozzles for the independent duct.
Part No.Part NameNotes
B3622Nozzle, rectangularFor absorbing smoke from the side. photo:FH800-03SVBuy Now
B3623Nozzle, roundFor absorbing smoke from above photo:FH800-03SVBuy Now
B3625Net (5 per pack)For preventing contaminants from being absorbed. (Mesh dimensions: Approx. 10 mm × 10 mm)photo:FH800-03SVBuy Now

-When using a bench top hood The benchtop hood detailed below requires the separate purchase of a different sized duct, duct band, and 3-inch adapter.
Part No.Part NameNotes
B2418Benchtop hoodFor stopping smoke from escaping upwards without being affected by air conditioning. photo:FH800-03SV *Requires ø75 duct, duct band (B2416), and 3-inch adapter (B3621).Buy Now
B2410DuctRequired when using benchtop hood. photo:FH800-03SV *ø75 x 2 m. Not freestanding.Buy Now
B2416Duct bandRequired when using benchtop hood. photo:FH800-03SVBuy Now
B3621Adapter (for 3-inch duct)Required when using benchtop hood and ø75 duct. photo:FH800-03SVBuy Now

Replacement Parts

photo:FH800-03SV
Part No.Name
A1572 Pre-Filters for the FA-430 (10 Pack)1. A1572Pre-filter (qty 10)Buy Now
A1573 Main Filter for the FA4302. A1573Main filterBuy Now
B3619 Cap3. B3619CapBuy Now
photo:FH800-03SV4. B1486Knob
B2852 Power Switch5. B2852Power SwitchBuy Now
B2425 Hakko British Standard Plug6. B2425Power Lead BS PlugBuy Now
Weight10.369 kg